HPCL Electrical Engineering Important Questions for Practice There are 24 Questions are Available in this article if you are interested this type of Questions please leave a feedback in Comment box
Q1. The two winding of a transformer is
Ans - Inductively Linked
Q2. A salient poles synchronous motor is running at no load . its field current is switched off. the motor will
Ans - Continue to Run at Synchronous Speed
Q3. The Dc series motor should always be started with load because
Ans - at no load , it will rotate at dangerously high speed
Q4. The frequency of rotor current in 3 phase 50 Hz , 4 pole induction motor at full load speed is
Ans - 2 Hz
Q5. In a Stepper motor the angular displacement
Ans - Can be precisely controlled
Q6. The power factor of a squirrel cage induction motor is
Ans - low at light load only
Q7. the generation voltage is usually
Ans - between 11kv to 33kv
Q8. When a synchronous motor is running at synchronous speed , the damper winding produces
Ans - No torque
Q9. If a transformer primary is energised from a square wave source , it output voltage will be
Ans - A square wave
Q10. In a dc series motor the electromagnetic torque developed is proportional to
Ans - 12a
Q11. In a 3-phase induction motor running at slip 's' the mechanical power developed in terms of air gap power pg is
Ans - (1 - SPg)
Q12. In a 3 - phase induction motor the maximum torque
Ans - Directly proportional Square of rotor induced EMF
Q13. In Dc machine the armature mmf is
Ans - Stationary W.r.t Field
Q14. In a transformer voltage regulation will be zero when operators is
Ans - Leading power factor
Q15. The maximum power in cylindrical and salient pole machine is obtained respectively at load angle of
Ans - Greater than 90
Pmax = EV/Xs
where , E = Excitation voltage
V = Terminal voltage
Xs = Synchronous reactance
sigma - load angle
Q16. The primary winding of a 220/6 v , 50 Hz supply . The secondary voltage will be
Ans - 3.0 v
Q17. The Emf induced in the primary of a transformer
Ans - leads the flus by 90 degree
Q18. The relative speed between the magnetic field of a stator and rotor under steady state operation is zero for a
a) DC Machine
b) 3-phase induction machine
c) synchronous speed
d) single phase induction machine
Ans - All options are correct
Q19. The current from stator of an alternator is taken out to the external load circuit through
Ans - solid connections
Q20. A motor which can conveniently be operated at lagging as well as leading power factor is the
Ans - synchronous motor
Q21. A hysteresis motor
Ans - is a constant speed motor
Q22. The most suitable servomotor for low power applications is
Ans - A Dc shunt motor
Q23. The size of conductor used in power cables depends on the
Ans - Current to be carried
Q24. Two winding single phase transformer has a voltage regulations of 4.5 % at full load and unity power factor . at full load and 0.8 power factor lagging load the voltage regulation will be
Ans - more than 4.5%